1.
Can J Infect Dis Med Microbiol ; 2023: 8508975, 2023.
Article in English | MEDLINE | ID: covidwho-2298969

ABSTRACT

Objective: This study aims to assess the effectiveness of surveillance inspections conducted by the provincial health committee in Quanzhou city during a COVID-19 outbreak in reducing false-positive results in SARS-CoV-2 RT-PCR assays. Method: The team conducted on-site inspections of laboratories that participated in mass screening, recording any violations of rules. Results: The positive cases in five rounds of mass screening were 23, 173, and 4 in Licheng District, Fengze District, and Luojang District, respectively. The false-positive rates in the five rounds of mass screening were 0.0099%, 0.0063%, 0.0018%, 0.0006%, and 0%, respectively. The study also recorded that the number of violations in the seven selected laboratories was 36, 68, 69, 42, 60, 54 and 47. The corresponding false-positive rates were 0.0012%, 0.0060%, 0.0082%, 0.0032%, 0.0060%, 0.0027%, and 0.0021%, respectively. The study found a positive correlation between false-positive rates and the number of violations (r = 0.905, P=0.005), and an inverse correlation between false-positive rates and the frequency of surveillance inspections (r = -0.950, P < 0.001). Conclusion: Daily surveillance inspection in laboratories can remind laboratories to strictly comply with standard procedures, focus on laboratory quality control, and reduce the occurrence of false-positive cases in SARS-CoV-2 nucleic acid tests to some extent. This study recommends that government decision-making departments establish policies and arrange experts to conduct daily surveillance inspections to improve laboratory quality control.

2.
Sensors (Basel) ; 21(16)2021 Aug 07.
Article in English | MEDLINE | ID: covidwho-1376954

ABSTRACT

In order to achieve high precision from non-contact temperature measurement, the hardware structure of a broadband correlative microwave radiometer, calibration algorithm, and temperature inversion algorithm are innovatively designed in this paper. The correlative radiometer is much more sensitive than a full power radiometer, but its accuracy is challenging to improve due to relatively large phase error. In this study, an error correction algorithm is designed, which reduces the phase error from 69.08° to 4.02°. Based on integral calibration on the microwave temperature measuring system with a known radiation source, the linear relationship between the output voltage and the brightness temperature of the object is obtained. Since the metal aluminum plate, antenna, and transmission line will have a non-linear influence on the receiver system, their temperature characteristics and the brightness temperature of the object are used as the inputs of the neural network to obtain a higher accuracy of inversion temperature. The temperature prediction mean square error of a back propagation (BP) neural network is 0.629 °C, and its maximum error is 3.351 °C. This paper innovatively proposed the high-precision PSO-LM-BP temperature inversion algorithm. According to the global search ability of the particle swarm optimization (PSO) algorithm, the initial weight of the network can be determined effectively, and the Levenberg-Marquardt (LM) algorithm makes use of the second derivative information, which has higher convergence accuracy and iteration efficiency. The mean square error of the PSO-LM-BP temperature inversion algorithm is 0.002 °C, and its maximum error is 0.209 °C.

SELECTION OF CITATIONS
SEARCH DETAIL